Limits and best practices

Daikin limits how many times Jeedom can query the cloud per day. This page explains why this limit exists and how to optimize it.

Why a limit?

To work, the plugin must regularly ask Daikin for your device status (temperature, mode, on/off, etc.). Each request counts toward a daily quota set by Daikin. This quota resets every day at midnight.

This is not a plugin limitation, but a rule imposed by the Daikin ONECTA cloud service.

Quota by connection mode

Connection mode Allowed requests per day
Developer Portal 200
Mobile App 3000

What consumes quota?

Action Consumption
Scheduled sync (every 15 min by default) 1 request (for all your devices at once)
Command (change temperature, turn on, etc.) 1 request per change
Verification after a command 1 request (depending on settings)
kWh counter update (each evening) 1 request
Real-time update (WebSocket, Mobile App mode) 0 requests

Important: one sync queries all your devices at once. Having 1 or 5 air conditioners consumes the same number of requests.

Estimate shown in configuration

On the configuration page (advanced section), the Scheduled requests/day field estimates how many GET requests the daemon will schedule each day, based on your day/night intervals, authentication mode, and WebSocket.

Configuration Detail Scheduled total
Developer Portal, defaults (15 min day, 30 min night, night 10 PM→7 AM) 60 day polls + 18 night polls + 1 energy stats ~79 GET/day
Mobile App + WebSocket enabled, same intervals Safety net 30/60 min: 30 + 9 + 1 ~40 GET/day

These figures do not include your commands, post-action refresh (depending on settings), or the daemon startup GET (+1 on each restart).

Optimization tips

Developer Portal mode (200/day)

  1. Keep default settings — they are designed for a good balance with the 200 requests/day quota.
  2. Do not reduce sync intervals below 15 minutes.
  3. Avoid scenarios that send many commands in quick succession.

If you use Mobile App mode (3000/day)

If you have many devices and automations

What happens when quota is reached?

The plugin automatically slows sync when quota is almost exhausted. Your commands still work, but state updates may be less frequent until the next day.

In Developer Portal mode, exceeding quota can block all requests until midnight.